Easy Weigh LS-100 Bedienungshandbuch

Stöbern Sie online oder laden Sie Bedienungshandbuch nach Küchenwaage Easy Weigh LS-100 herunter. Easy Weigh LS-100 Owner`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Easy Weigh
OWNER’S MANUAL
MODEL: LS-100
LABEL PRINTING SCALE
VER 2.00
®
Seitenansicht 0
1 2 3 4 5 6 ... 75 76

Inhaltsverzeichnis

Seite 1 - Easy Weigh

Easy Weigh OWNER’S MANUAL MODEL: LS-100 LABEL PRINTING SCALE VER 2.00 ®

Seite 2 - Disclaimer:

6 The Printer Cassette is a drawer mechanism that is pulled out of the scale in order to load new label rolls or service the printer. The Thermal P

Seite 3 - TABLE OF CONTENTS

7 The Fuse Holder contains a 1.6A 250V 20mm safety fuse. You may need a flat screw driver to open the fuse holder but make sure that the scale is u

Seite 4

8 The Insert Lamp works with the Ins key. When on, it means that the scale is in insert-text mode; when off, it means that the scale is in overwrit

Seite 5 - Specifications

9 Make sure that the Power Switch is off. Pull on the cassette handle to remove the cassette drawer. Once you have removed the cassette

Seite 6 - Support & Service

10 Installing Labels: Once you have followed the instructions for removing labels you can install a new label roll by taking the new label roll and

Seite 7 - Box Contents

11 9) Finally, slide the cassette drawer back into the scale making sure to align the Metal Rails (k) of the cassette with the Plastic R

Seite 8 - Scale Overview

12 SET Key is used to enter the Main Menu (programming mode.) You may be required to enter a password to access programming mode. Numeric Keys (0

Seite 9

13 There is a Speed Key Template which you can pull out of the Alpha Keypad. This template can be used to write or label each of the 60 keys. You

Seite 10

14 S1 Key reserved for future use. S2 Key changes between languages: when the Lang Lamp is off, then the scale is in English typing; when on, the

Seite 11 - Displays

15 Do’s & Don’ts Please observe the following:  Unplug and shut the scale OFF whenever you are changing the label roll or working in the p

Seite 12

PREFACE Easy Weigh® would like to thank you for purchasing our model LS-100 Price Computing Label Printing

Seite 13

16 Location & Environment This scale must be placed on a flat and stable surface. Please keep the scale away from the direct path of ventil

Seite 14

17 The keyboard should be cleaned with a damp cloth rag and a mild soap solution. Do NOT spray any liquids or chemicals directly onto the keyboard

Seite 15 - Numeric Keypad

18 To clean the TPH, begin by removing the cassette drawer from the scale. Next, using a cotton swab dipped in Denatured Alcohol, gently slide the

Seite 16 - Speed Keys

19 free. With that in mind, please make sure that the power outlet used with the LS-100 is a dedicated line with no high-noise devices (such as co

Seite 17 - Alpha Keypad

20 b. Place the Pole Display properly into the bracket making sure that the connectors are slipped inside of the pole (upwards.) c. Attach the

Seite 18 - Safety First

21 Password When you purchase an LS-100, it comes with password protection by default. The initial password is “0000”; four zeroes. You can di

Seite 19 - Do’s & Don’ts

22 Main Menu The Main Menu is where you can set all of your PLU programming, system options, and sales reports. The LS-100 menu tree is organiz

Seite 20 - Maintenance

23 To enter Main Menu: 1. Start From the Initial State and press SET . 2. Enter the correct password and press PRINT . 3. The Main Menu display a

Seite 21

24 Store Name & Address You can print the store name and address or any other pertinent information, at the bottom of each label; however, n

Seite 22 - Power Requirements

25 Groups In order to better sort your PLUs, you can assign each PLU to any 1 of 99 groups. Just like PLUs can be named, each of the 99 groups

Seite 23 - Quick Start

i TABLE OF CONTENTS General Introduction …………………………………………….. 1 Specifications ………………………………………….. 1

Seite 24

26 Group Assignment Just like you can assign a PLUs to a certain groups, you can also assign a scale to a specific group. A new scale is assign

Seite 25 - Input Password

27 The LFA (Label Feed Adjustment) adjusts the print position of a label. It is independent of the LFS number and can range from 0 to 40; 20 being

Seite 26 - Main Menu

28 Password Change You can change the password to any 4 digit number you want. The initial password is “0000”; four zeroes. If your scale has

Seite 27 - ENTER PLU

29 Creating & Editing PLUs Price Look Ups (PLUs) are the basic stock units of the LS-100 scale and are also referred to Stock Keeping Unit

Seite 28 - Scale Number

30 When food is sold by weight, it must be accurately weighed and labeled with certain specific data whose requirements may change according to jur

Seite 29 - . Edit Group

31 To Create or Edit PLUs: 1. Follow steps 1 to 3 of entering Main Menu. 2. Press 1 . The displays will show: PLU - 0. PLU Number 3. Enter

Seite 30 - Label Settings

32 8. The next screen is the Commodity Name Line 2. This is the second line of your PLU name descriptor. It can be up to 56 characters long; alth

Seite 31

33 14. If you are creating a By Weight PLU, go to step 16. This is where you assign Piece count to a By Count PLU. The Pieces value defaults to b

Seite 32 - Password Change

34 The PLU Shelf Life screen appear as follows: By Weight By Count PLU - 6. Shelf Life PLU - 7. Shelf Life 19. You can press SAVE to

Seite 33 - Creating & Editing PLUs

35 23. You can press SAVE to store the PLU as-is and go to step 28 or you can press PRINT to continue to step 24. 24. The next screen is the PLU

Seite 34

ii Sensor Settings ……….………………………………. 41 Barcode Settings ….….………………………………. 42 Backlight Settings …………

Seite 35 - 1.By Weight 2.By Count

36 If you press Y then the PLU will be stored; if you press N then the PLU will NOT be stored. Then you will see the following screen: 2.

Seite 36 - PLU - 4. UPC Code

37 Speed Keys The LS-100 has 60 Speed Keys that can be assigned PLU numbers so that PLUs can be quickly accessed in Sales mode. By default, Spe

Seite 37 - PLU - 5. Price

38 4. If the PLU you selected is By Weight then go to step 6. The Unit Price and Total Price displays will show the current Piece count of the se

Seite 38

39 Print Field Suppression The LS-100 can prevent certain fields from printing on your labels. You may want to not print barcodes, store names,

Seite 39 - Save Changes?(Y/N)

40 14. The next field is “Store Name.” If 0 is selected then the Store Name will not print; if 1, then only Line 1 of the Store Name will print; i

Seite 40 - . PLU Speed Keys

41 Sensor Settings The LS-100 can use the Gap Sensor or the Peel Sensor to Sense gaps between labels. If you constantly get the error message “

Seite 41 - PLU Quick Price Change

42 Barcode Settings The LS-100 can print 3 different barcode styles: UPC-A, UPC-B, and EAN-8. UPC-A is a 12 digit barcode and has been the pre

Seite 42 - Deleting PLUs

43 One last tip regarding POS systems: POS systems are usually personal computers that “look like” ECRs; whereas, ECRs are hardware devices that a

Seite 43 - Print Field Suppression

44 Script Characters Definition 0 to 9 Will print the actual numbers 0 to 9. I UPC Code, acquired from the PLU. V Price checksum P Total Price

Seite 44 - Temporary Date Print Inhibit

45 Auto Print Setting When the LS-100 is in Pre-Pack mode, it is capable of auto printing labels. This feature is very useful for pre-packing;

Seite 45 - Sensor Settings

1 Introduction The LS-100 Label Printing scale has been designed with many advanced features, user-friendly menu driven programming, and high qua

Seite 46 - Barcode Settings

45 PLU List The LS-100 can display or print a list of all the scale’s PLUs. This can be very helpful when you do not have the LS-100 Software P

Seite 47

47 4. As you type, the number will appear in the Total Price Display. Press PRINT . Now select the last (ending) PLU number for your list. The

Seite 48 - Date Format

48 PLU Memory Status If you ever want to know how much more memory space you have left or how many more PLUs you can program, you can use this f

Seite 49 - Auto Print Setting

49 This blueprint will always work assuming that you have a non-zero Total Price. You may want to use a different tare than that of the PLU that y

Seite 50 - GROUND BEEF

50 The Zero Key You can use the ZERO key to correct a deviation from zero so long as there is no PLU called up and the “Net” Lamp is off. You

Seite 51 - Deleting All PLUs

51 The Tare Key You can use the TARE key to override a PLU’s preset tare, enter a sampled a tare, enter a manual tare, or clear a tare. Sampl

Seite 52 - PLU Memory Status

52 Clearing preset tares: Sometimes you may want to temporarily remove the preset tare of a PLU. You can only do this ONLY if you set the Allow Te

Seite 53 - Miscellaneous PLUs

53 Whenever the Save Lamp is on it means that the scale will not use the ACF. You can turn the Save function on or off by pressing SAVE . To turn

Seite 54 - The Zero Key

54 Pre-Pack mode and AUTO + SAVE are very similar but differ in that Pre-Pack mode…  Automatically prints By Count and By Weight PLUs  Allows

Seite 55 - The Tare Key

55 The Func. Key (Void key) The Func. key acts like a sales voiding key whenever you are in Sales mode. It is used to subtract the price of d

Seite 56 - The Save Key

2 Options & Accessories The following options are available through your Easy Weigh dealer: Description Part Number Fish Pan Platter260-100

Seite 57 - The Pre-Pack Key

56 The For Key The FOR key is used to toggle between the Piece count and the Price for By Count PLUs. It is also used to convert By Weight PL

Seite 58 - The Esc Key

57 The labels issued from the FEED key have a special “checkered” pattern printed on them. This pattern is there to let you know the status of th

Seite 59 - The X Key

58 If you clean the TPH (see Maintenance section) and any of these problems persist, then it is possible that the platen may be damaged or that the

Seite 60 - The Feed Key

59 The Clear key is also used in Program mode to clear text. If the cursor is on a text field (Alpha Display) and you press C , then all of the t

Seite 61

60 X: Group Sales The LS-100 has the ability to keep track of the sales transactions that it issues. It can keep sales records based on group

Seite 62 - The Clear Key

61 X: PLU Sales When you perform a PLU Sales Report, the scale will print a report on active PLUs or the ones you specify. Active PLUs are PLU

Seite 63

62 Z: Scale Sales When you perform a Scale Sales Report, the scale will print a Scale Sales Report and then clear all sales data. Once you do

Seite 64 - X: Group Sales

63 Scale Reports page 2: The 1st line contains the report name and the page number (2 of 2.) The 2nd line contains today’s date and the scale num

Seite 65 - X: PLU Sales

64 Scale to Scale Data Transfer You can transfer scale data from one scale to another; in essence, you can clone a scale. This is NOT a network

Seite 66 - Z: Scale Sales

65 PC to Scale Data Transfer You can use your PC to store data files for the LS-100 scale, all you need to do is to purchase the LS-100 Software

Seite 67

3 Box Contents Your LS-100 scale should come with the following: NO Parts Name Units QTY 4-1 IN CARTON BOX EA 1 4-2 STYROF

Seite 68 - Scale to Scale Data Transfer

66 Apendix A: Label Format Library Appendix A: Label Format Library You can use this section to determine the label format number that correspo

Seite 69 - Self Test

Apendix A: Label Format Library 67 To change the label format number from the Main Menu: Press 7 2 , enter the format # and press PRINT ESC .

Seite 70

68 Apendix A: Label Format Library To change the label format number from the Main Menu: Press 7 2 , enter the format # and press PRINT ESC .

Seite 71

Apendix A: Label Format Library 69 To change the label format number from the Main Menu: Press 7 2 , enter the format # and press PRINT ESC .

Seite 72

70 Apendix A: Label Format Library Note on Label Formats: Label formats are subject to change without notice. Easy Weigh or any Easy Weigh Deal

Seite 73

71 Notes: You Easy Weigh Dealer is:

Seite 74

Easy Weigh www.atronsystems.com Copyright 2005, All rights reserved. 800-17007-02000E

Seite 75

4 Assembling the Display Once you have unboxed your LS-100 you must carefully follow the instructions be

Seite 76

5 Front View: The Weight Display is where all weight data is displayed. The Unit Price Display is where the scale displays price-per-pound data as

Kommentare zu diesen Handbüchern